STUDY OF THE COMPARATIVE EXPERIMENT ON SIMPLE BEAMS AND FRAME BEAMS STRENGTHENED BY EXTERNALLY PRESTRESSED TECHNOLOGY
-
摘要: 通过一组体外预应力加固简支梁与框架梁的对比试验,验证了由于竖向构件侧向约束的影响,造成竖向构件剪力增大,横向水平构件有效预应力降低的理论。通过分析研究这种影响的程度与后果认为,工程施工框架、剪力墙等多、高层预应力混凝土结构中应考虑梁的次轴力,并提出如何增强竖向构件抗剪能力的建议。Abstract: A comparative experiment on the externally prestressed simple beams and frame beams is conducted. Through this experiment, the theory is proved that shearing force of frame columns is enhanced and effective prestressing of horizontal members is decreased because of effective lateral restraint of the frame columns. And the suggestions are proposed that secondary axial force in frame and shear wall structure must be considered and that of how to increase shearing capacity of frame columns.
-
[2] 陆益鸣,陆道渊.考虑侧向刚度影响的预应力混凝土梁正截面极限强度分析PP中国预应力技术五十年暨第九届后张预应力学术交流会论文集.北京:2006:140-144 郑文忠,周威.预应力混凝土侧向约束影响的分析方法.哈尔滨建筑大学学报,2001(6) : 12-16 [3] 张瑞云,曹双寅.侧向约束对体外预应力加固框架梁承载能力影响分析.工业建筑,2005,35(4):35-37 [4] 蔡 跃,黄鼎业,熊学玉 等.预应力梁受柱抗侧刚度影响分析及设计建议.特种结构,2003(1):1-3 [5] 王少喻.体外预应力加固混凝土梁体外筋应力增量研究: [硕士学位论文].桂林: 桂林工学院,2007 [6] 田爱菊.钢筋混凝土简支梁体外预应力加固法的抗弯性能研究:[硕士学位论文].桂林:桂林工学院,2007
点击查看大图
计量
- 文章访问数: 65
- HTML全文浏览量: 5
- PDF下载量: 39
- 被引次数: 0