EXPERIMENTAL RESEARCH ON UNBONDED POST-TENSIONED PRECAST CONCRETE BEAMS
-
摘要: 对4个无粘结预应力装配梁试件进行低周反复加载试验,考虑预应力筋偏心位置、锚固长度、初始预应力度等参数变化。结果表明:无粘结预应力装配梁具有令人满意的抗震特性,与现浇混凝土结构相比虽然耗能低,但延性好自恢复能力强(残余变形小),较非线性大位移下试件破坏程度轻。分析了装配梁的恢复力特性、延性、耗能等性能与试验参数的关系,为无粘结预应力装配结构在地震地区的使用提供参考。
-
关键词:
- 后张无粘结预应力装配梁 /
- 低周反复加载 /
- 自恢复能力 /
- 耗能 /
- 抗震性能
Abstract: It is researched 4 unbonded pos-t tensioned precast concrete beams under reversed cyclic loading. In this study there are some parameters that are taken into account, such as PT eccentric position, PT anchor length and initial pos-t tensioning load. Experiment shows that these beams used unbonded pos-t tensioned tendon have desirable seismic characteristics such as a sel-f centering capability and an ability to undergo large nonlinear displacements with little damage. Some seismic behaviors such as resilience, ductility, energy dissipation etc are analyzed. The objective of this test is to develop guidelines for precast structure in regions of earthquake zone. -
[2] 李振宝, 董挺峰, 闫维明, 等. 混合连接装配式框架内节点抗震性能研究. 北京工业大学学报, 2006, 32 (10) : 895-900 董挺峰, 李振宝, 周锡元, 等. 无粘结预应力装配式框架内节点抗震性能研究. 北京工业大学学报, 2006, 32 (2) : 144-148 [3] Park R. The Design and Construction of Structural Concret e for Seismic Resistance. Proceedings of the 13th FIP Congress On Challenges for Concrete in the Next Millennium, Amsterdam. 1998(2) : 873-878 [4] 董挺峰, 李振宝, 周锡元. 装配式混凝土框架结构及其抗震性能研究. 建筑技术, 2006, 37 (11) : 844-847 [5] Minehiro Nishiyama, Masato Adachi, Fumio Watanabe. Hysteretic Behavior of Precast Prestressed Concrete Beam-Column Assemblage.Proceedings of the 13th FIP Congress on Challenges for Concrete in the Next Millennium, Amsterdam. 1998(1) : 177-182 [6] Englekirk Robert E J. Development and Test ing of a Duct ile Connector for Assembling Precast Concrete Beams and Columns. PCI Journal, 1995, 40(2) : 36-51 [7] 林同炎. NED. BURNS. 预应力混凝土结构设计(第三版). 北京:中国铁道出版社, 1983: 152-180 [8] JGJ 140-2004 预应力混凝土结构抗震设计规程 JGJ 92-2004 无粘结预应力混凝土技术规程
点击查看大图
计量
- 文章访问数: 92
- HTML全文浏览量: 10
- PDF下载量: 81
- 被引次数: 0