EXPERIMENT ON A NEW AXIALLY LOADED COLUMN OF CONCRETE FILLED PREFABRICATED TUBULAR MEMBERS
-
摘要: 对一种新型的预制管混凝土柱结构与钢筋混凝土现浇柱,以体积配箍率和预制管的混凝土轴心抗压强度为参数,进行对比试验。用二轴强度理论计算预制管混凝土柱的开裂荷载,并在本次试验和以往理论研究的基础上,给出预制管混凝土柱轴心受压承载力计算公式。Abstract: A new style of composite column(the column of concrete filled prefabricated tubular members) and cas-t in-place concrete column are studied in this paper, whose main parameters are stirrup ratio and concrete strength of the prefabricated tubular members. According to the analysis of the stress state of the prefabricated tubular members with the biax ial strength criterion of concrete under axial pressure, a formula is presented for general calculation of the cracking load. And according to the experimental data, the formula of ultimate axial compressive strength of the column of concrete filled prefabricated tubular members is obtained.
-
建工部建筑科学研究院建筑结构研究所. 预应力薄板性能及设计计算. 北京: 建工部建筑科学研究院, 1967 [2] 郑锦图, 何新基. 预应力混凝土叠合板的试验研究. 武汉: 湖北省建工局科研所, 1980 [3] GB 50010-2002 混凝土结构设计规范 [4] 周栋梁, 程丽荣, 钱稼茹. 普通箍筋约束混凝土柱的中心受压性能. 清华大学学报(自然科学版), 2002, 42(10) [5] 罗苓隆, 过镇海. 箍筋约束混凝土的受力机理及应力-应变全曲线的计算. [科学研究报告]. 北京: 清华大学出版社, 1996
点击查看大图
计量
- 文章访问数: 54
- HTML全文浏览量: 3
- PDF下载量: 41
- 被引次数: 0