CALCULATION AND ANALYSIS OF BEARING CAPACITY OF INNER PRESSURE OF CONTAINMENT STRUCTURE IN NUCLEAR POWER PLANT
-
摘要: 安全壳结构的承载能力计算分析需要考虑钢绞线和混凝土的力学特性。采用正交异性膜单元模拟正交方向的预应力钢束,并分析预应力损失随时间的变化,对服役的安全壳进行有限元分析,提出安全壳结构的分析步骤。以某核电厂安全壳结构的分析与试验数据对比,证明了方法的可行性,并对安全壳进行了极限承载力分析。Abstract: The mechanical properties of steel wires and concrete should be considered in the calculation and analysis of containment structure.The prestressed steel wires are simulated using orthotropic material properties membrane element.The finite element analysis of containment in service is based on dynamic prestressing losing of steel wires with time and the steps of analysis are put foward.Taking a nuclear power plant containment for example,the result of comparison between calculation data and the measuring data shows the feasibility of this way of analysis.The ultimate bearing capacity of containment structure is also analyzed.
-
Key words:
- containment structure /
- finite element /
- prestressing
-
.夏祖讽,王明弹,黄小林. 百万千瓦级核电厂安全壳结构设计与试验研究[J].核动力工程,2002,(zk):123-129.doi: 10.3969/j.issn.0258-0926.2002.z1.027. .GB 50010-2002.混凝土结构设计规范[S]. .朱伯芳. 有限单元法原理与应用[M].北京:中国水利水电出版社,1998. .董哲仁. 钢筋混凝土非线性有限元法原理与应用[M].北京:中国水利水电出版社,2002.135-145. .陈勤,钱稼茹. 内压荷载下安全壳1:10模型结构非线性有限元分析[J].工程力学,2002,(06):73-77.doi: 10.3969/j.issn.1000-4750.2002.06.015. .张会东. 核电厂安全壳结构安全评估与激光自动变位测量系统的研究与开发[D].中冶集团建筑研究总院,2005.