EXPERIMENT ON ANTI-SEISMIC BEHAVIOR OF LIGHT GAUGE STEEL REINFORCED CONCRETE SHEAR WALL
-
摘要: 根据我国产业政策和建筑节能的要求,在主要城市取消和限制使用黏土砖建设多层建筑,为此提出一种新型结构即轻钢骨混凝土剪力墙结构取代砖混结构,并对该类墙体的抗震性能进行试验研究。通过5个缩尺轻钢骨混凝土剪力墙在低周反复荷载下的试验,对其承载力、破坏形态、滞回性能、耗能性、延性及其刚度退化情况等进行分析。研究结果表明,该类结构的受力性能良好,满足抗震性能要求。Abstract: Based on demanding of a industry policy and economical energy source in our country, multi-story masonry have been limited in cities. Therefore, a new kind of structure-light gauge steel reinforced concrete shear wall is suggested herein instead of brick masonry. Five light gauge steel reinforced concrete shear walls subjected to cyclic loading are experimented. And the seismic behaviors, such as bearing capacity, failure pattern, hysteretic property, energy dissipation, ductility and declining stiffness of light gauge steel reinforced concrete shear wall, are analyzed by the experiments. Research results indicate that this structure has good forced behavior, which can meet the aseismic requirements.
-
钱稼茹,吕文,方鄂华. 基于位移延性的剪力墙抗震设计[J].建筑结构学报,1999,(03):42-49. Peter Sheppard. The Influence of Horizontally Placed Reinforcement on the Shear Strength and Ductility of Masonry Walls[J].ACI Structural Journal,1993,(04):385-392. 沈聚敏,周锡元,高小旺. 抗震工程学[M].北京:中国建筑工业出版社,2002.
点击查看大图
计量
- 文章访问数: 104
- HTML全文浏览量: 6
- PDF下载量: 88
- 被引次数: 0