摘要: 利用有限元分析软件ANSYS对火灾情况下钢-混凝土组合柱的温度场进行分析,获得了构件截面温度场的分布规律,计算结果与试验结果吻合良好,从而为进一步深入认识钢-混凝土组合结构的高温下力学性能创造了条件。Abstract: The thermal field of steel-concrete composite columns under fire is analyzed by finite element analysis software ANSYS and the distributing circumstance of section thermal field is gotten.The calculated results agree well with those of tests and the achievements make it possible to study further the mechanical performance of steel-concrete composite structures at high temperature.
-
Key words:
- ANSYS /
- steel-concrete composite structure /
- column /
- finite element /
- thermal field
-
[2] 陶忠,韩林海,黄宏.方中空夹层钢管混凝土偏心受压柱力学性能的研究.土木工程学报,2003,36(2):33-40 韩林海.钢管混凝土结构--理论与实践.北京:科学出版社,2004 [3] 孔祥谦.有限单元法在传热学中的应用.北京:科学出版社,1998 [4] ECCS-Technical Committee 3.Fire Safety of Steel Structures,Technical Note,Calculation of the Fire Resistance of Centrally Loaded Composite Steel-Concrete Columns Exposed to the Standard Fire.1988 [5] ISO-834 Fire Resistance Tests-Elements of Building Construction [6] Lie T T.Fire Resistance of Circular Steel Columns Filled with Bar-Reinforced Concrete.Journal of Structural Engineering,1994,120 (5):1 489-1 509 [7] Lie T T,Chabot M.A Method to Predict the Fire Resistance of Circular Cncrete Filled Hollow Steel Columns.Journal of Fire Protection Engineering,1990,2(4):111-126 [8] 过镇海,时旭东.钢筋混凝土的高温性能及其计算.北京:清华大学出版社,2003 [9] Lie T T,Chabot M.Experimental Studies on the Fire Resistance of Hollow Steel Columns Filled with Plain Concrete.NRC-CNRC Internal Report,Ottawa:1992 [10] Lie T T,Celikkol B.Method to Calculate the Fire Resistance of Circular Reinforced Concrete Columns.ACI Material Journal,1991,88(1):84 -91 [11] Lie T T,Irwin R J.Method to Calculate the Fire Resistance of Reinforced Concrete Columns with Rectangular Cross Section.ACI Structural Journal,1993,90(1):52-60
点击查看大图
计量
- 文章访问数: 84
- HTML全文浏览量: 10
- PDF下载量: 99
- 被引次数: 0