EXPERIMENTAL RESEARCH ON FIRE RESISTANCE OF H-SECTION STEEL COLUMN
-
摘要: 对2根H型截面钢柱进行了火灾行为的试验研究。采用足尺试验形式,柱长3 300mm,钢柱在试验过程中限制轴向变形。通过试验,得出了钢柱在火灾下的侧向变形和轴向约束力情况。试验表明,限制轴向变形对钢柱火灾行为产生明显的影响,二次受火钢柱极限温度明显降低。为今后钢结构火灾行为研究提供依据。Abstract: The behaviour of two H_section steel columns under fire is investigated.All columns are full scale with(3 300mm) length under axial restraint.From the test results,the regularities of lateral deflection and axial restraint force are presented.The test results show that the behaviour of steel columns under fire is influenced by restrained thermal elongation.Limit temperature decreases if steel columns are subject to fire again.Which provides a basis for further research to explore fire behaviours of steel structures.
-
Key words:
- fire /
- H-section steel column /
- lateral deflection
-
[2] 陈绍蕃.钢结构设计原理.北京:科学出版社,2001 Faris Ali,David O' Conner.Structural Performance of Rotationally Restrained Steel Columns in Fire.Fire Safety Journal,2001,36:679-691 [3] 陈骥.钢结构稳定理论与设计.北京:科学出版社,2003 [4] 沈祖炎,陈扬骥,陈以一.钢结构基本原理.北京:中国建筑工业出版社,2000 [5] 魏明钟.钢结构,武汉:武汉理工大学出版社,2002 [6] 日本钢结构协会.钢结构技术总览[建筑篇].陈以一,傅功义,译.北京:中国建筑工业出版社,2003 [7] 李国强,贺军利,蒋首超.钢柱的抗火试验与验算.建筑结构,2000,30(9):12-15 [8] Franssen J M,Talamona D,Kruppa J,et al.Stability of Steel Columns in Case of Fire:Experimental Evaluation.Journal of Structural Engineering,1998(2):158-163 [9] Toh W S,Tan K H,Fung T C.Compressive Resistance of Steel Columns in Fire:Rankine Approach.Journal of Structural Engineering,2000:398-405 [10] 李国强,杨明,王兆玺.钢柱抗火计算和设计的实用方法.工业建筑,1995,25(2):31-37 [11] 李晓东,董毓利,丛术平.柔性连接钢梁火灾行为的试验研究.西安建筑科技大学学报,2005,37(2):169-173 [12] 李晓东,董毓利,吕俊利.轴心受压H型截面钢柱火灾行为的试验研究.实验力学,2005,20(3):328-334
点击查看大图
计量
- 文章访问数: 53
- HTML全文浏览量: 4
- PDF下载量: 87
- 被引次数: 0