THE EVALUATION OF PRESTRESSING LOSS IN EXTERNALLY PRESTRESSED CONCRETE STRUCTURE
-
摘要: 体外预应力结构的构造形式及施工方法与有粘结或无粘结预应力结构有较大差别,因此,其产生的预应力损失也不同。结合体外预应力结构自身特点,对其设计阶段预应力损失的估算进行了探讨,并提出了相关的设计计算建议。Abstract: The structure and construction method of externally prestressed structures differ greatly from structures with bonded or unbonded tendons, therefore generate the difference in prestressing loss. In this paper, the calculation method of prestressing loss are discussed, and applicable formulae are suggested with regard to the characteristic of external prestressing.
-
Key words:
- external prestressing /
- prestressing loss
-
GB 50010-2002 混凝土结构设计规范 [2] 陈晓宝,等.预应力混凝土结构中空间索线筋的预应力摩擦损失计算.土木工程学报,2003,36(6):26~30 [3] 华毅杰,熊学玉,黄鼎业.体外预应力结构加固设计方法的探讨.见:世纪之交的预应力新技术.北京:专利文献出版社,1998 [4] 华毅杰,熊学玉,刘华波.体外预应力技术在加固和改造工程中的应用.结构工程师,1999(4):38~41 [5] 过镇海.钢筋混凝土原理.北京:清华大学出版社,1999 [6] 孔保林.体外预应力加固体系的预应力损失估算.河北建筑科技学院学报,2002,19(3):27~29 [7] Comit Euro-International du Bton.CEB-FIP Model Code.1990 [8] 熊学玉,蒋志贤.预应力摩擦损失的合理设计建议.结构工程师,1997(4) [9] 郑毅敏,熊学玉,耿耀明.体外预应力混凝土结构设计若干问题的探讨.工业建筑,2000,30(5):24~28